Product Manual

wc_tx001332gb_FM10.fm
37
PD2A / PD3A Maintenance
5.6 Cleaning the Sediment Cup
When
Clean the engine sediment cup every 100 hours or 6 months.
Requirements
Machine shut down
Nonflammable solvent
Procedure
Perform the procedure below to service the sediment cup.
1. Stop the engine.
2. Set the fuel valve to the OFF position.
3. Remove the sediment cup (a) and the O-ring (b).
4. Wash the sediment cup and the O-ring thoroughly in a nonflammable solvent.
Dry and re-install them.
5. Set the fuel valve to the ON position and check for leaks.
WARNING
Fire hazard. Gasoline or low-flash-point solvents are flammable and may ignite if
used to clean the machine.
Use only nonflammable solvents when cleaning the sediment cup.