Product Manual
wc_tx001331gb_FM10.fm
29
PD2A / PD3A Operation
4.9 Running the Pump
Guidelines
Follow the guidelines below when running the pump.
■ Run the engine at full speed.
NOTICE: Pump speed must not exceed 60 strokes per minute (2800 rpm).
■ The pump should begin pumping water within one minute of being started
depending on hose length and height above water. Longer hoses will require
more time.
■ If the pump does not prime:
a.check for loose fittings, air leaks, and plugged strainer.
b.stop the engine, remove plug (a), add water, re-install plug, and restart the
engine.