PD2A / PD3A Operation
4.9 Running the Pump
Guidelines
Follow the guidelines below when running the pump.
Run the engine at full speed.
NOTICE: Pump speed must not exceed 60 strokes per minute (2800 rpm).
The pump should begin pumping water within one minute of being started
depending on hose length and height above water. Longer hoses will require
more time.
If the pump does not prime:
a.check for loose fittings, air leaks, and plugged strainer.
b.stop the engine, remove plug (a), add water, re-install plug, and restart the
engine.