Repair manual

PD Technical Data
wc_td000178gb.fm 11
2.2 Pump—Machines with Honda Engines
2.3 Sound Measurements—Machines with Honda Engines
The required sound specification, Paragraph 1.7.4.f of 89/392/EEC
Machinery Directive, is:
the guaranteed sound power level (L
WA
) = 96 dB(A).
the sound pressure level at operator’s location (L
pA
) = 82 dB(A).
These sound values were determined according to ISO 3744 for the
sound power level (L
WA
) and ISO 6081 for the sound pressure level
(L
pA
) at the operator’s location.
Item Number:
PDT/PDI 2A
0007610, 0007611
0007624, 0007625
PDT/PDI 3A
0007614, 0007615,
0007616, 0007628,
0007629, 0009407
Pump
Weight
kg (lbs.)
52 (114) 63 (138)
*Max. Suction Lift
m (ft.)
7.5 (25)
Max. Discharge Head
m (ft.)
7.5 (25)
Max. Total Head
m (ft.)
15 (50)
Max. Discharge
Pressure
kg/cm
2
(psi)
0.76
(10.8)
Max. Discharge Flow
m
3
h (gpm)
11 (50) 20 (88)
Gear Case Lubrication
oil grade
ml (oz.)
SAE 80W-90
532 (18)
SAE 80W-90
532 (18)
Suction / Discharge Dia.
mm (in.)
50 (2) 75 (3)
Maximum Solid Size
mm (in.)
30 (1.25) 45 (1.75)
* Based on pump operating at sea level. Maximum suction lift will be less at higher altitudes.