Operator`s manual

Technical Data PD 2/3
wc_td000144gb.fm 22
4.2 Pump
4.3 Sound Measurements
The required sound specification, Paragraph 1.7.4.f of 89/392/EEC
Machinery Directive, is:
the guaranteed sound power level (L
WA
) = 96 dB(A).
the sound pressure level at operator’s location (L
pA
):
PDT 2 = 78.8, PDT 3 = 82.
These sound values were determined according to ISO 3744 for the
sound power level (L
WA
) and ISO 6081 for the sound pressure level
(L
pA
) at the operator’s location.
Item Number:
PDI/PDT 2
0009489, 0009494
PDI/PDT 3
0009491, 0009492,
0009495
Pump
Dimensions
(L x W x H)
mm
(in.)
1010 x 630 x 570
(40 x 25 x 22.5)
1010 x 745 x 605
(40 x 29.3 x 24)
Operating Weight
kg (lbs.)
52 (114) 61 (133)
*Max. Suction Lift
m (ft.)
7.5 (25)
Max. Discharge Head
m (ft.)
7.5 (25)
Max. Flow Rate
l/m (gpm)
189 (50) 333 (88)
Gear Case Lubrication
oil grade
ml (oz.)
SAE 80W-90
532 (18)
Suction / Discharge Dia.
mm (in.)
50 (2) 75 (3)
Maximum Solid Size
mm (in.)
32 (1.25) 45 (1.75)
* Based on pump operating at sea level. Maximum suction lift will be less at higher altitudes.