Testing a
GFCI
receptacle
Perform the manual test procedure below before each use to test a GFCI
receptacle.
1. Turn the power on at the control
panel.
A green LED power on indication
light (a) will illuminate on the GFCI
receptacle.
2. Push the test button (b) in.
The reset button (c) should pop
out.
Power to the GFCI receptacle
should be off.
3. Push the reset button in.
A green LED power on indication
light will illuminate on the GFCI
receptacle.
In addition to the manual test shown
above, the GFCI receptacle has a self-
test feature. The red LED failure
indication light (d) will flash if the GFCI
receptacle has lost its GFCI protection.
Do not use the GFCI receptacle until it is
replaced.
wc_gr014322
INSTRUCTIONS
MONTHLY
SEE
TEST
TEST
TEST
RESET
RESET
REPLACE GFCI
IF RED
LIGHT FLASHES