Product Manual
wc_tx004431en.fm
54
Operation LTV
5 Operation
5.1 Generator Derating
Description
All generator sets are subject to derating (reduced power output) depending on the
altitude and ambient temperature. Derating should not affect the operation of the
floodlights, although it will reduce the available reserve power to the receptacle.
Derating
percentages
Power ratings are typically reduced by the following percentages:
■ 3% per 300 m (1000 ft) elevation above sea level
■ 2% per 5.5°C (10°F) increase in ambient temperature above 25°C (78°F).
5.2 Control Panels and Receptacles—KUBOTA
wc_gr013749
a
b d
c
a
b
c
e
f
6K 8K
6K
g
h
j
k
m m
n
8K
n
p
Ref. Description Ref. Description
a Main circuit breaker h Shore power switch (optional for 6K)
b GFCI circuit breaker j Control panel light
c Lights circuit breaker k 30A receptacle breaker (standard for 8K)
d Tower winch rotary switch (optional) m 20A GFCI receptacle
e Key switch n 30A receptacle
f Glow plug indicator p Shore power inlet (optional for 6K)
g Hour meter — —