Product Manual
13 Technical data
100_0101_td_0026.fm 27
13 Technical data
13.1 IEC45
Designation Unit IEC45/120/3 US IEC45/120/8 US
Item no. 5100036227 5100036228
Rated current A 8,0
Rated voltage V 120
Rated frequency Hz 50 – 60
Rated input power ** kW 0,56
Phases ~ 1
Vibration range in air mm (in) 2,3 (0.09)
Vibrations rpm 12,000
Hz 200
Vibrator head diameter mm (in) 45 (1.8)
Outer diameter of protective hose mm (in) 31 (1.2)
Length of vibrator head mm (in) 320 (12.6)
Length of protective hose m (ft) 3 (9.8) 8 (26.4)
Length of power cable *** m (ft)
5 (16.4)
Weight kg (lb) 10,8 (23.8) 14,6 (32.2)
Plug NEMA 5-15P (type B)
Engine type Asynchronous motor
Oil specification 4 UH1- 46N
Oil quantity l 0,006
Class rating l
Protection class IP 67
Storage temperature range °C (°F) -20 – +60
(-4 – +140)
Operating temperature range °C (°F) -10 – +40
(+14 – +104)
Sound pressure level L
pA
* dB(A) 79
Standard EN 12649
Vibration total value a
hv
m/s
2
(ft/s
2
)
< 2,7
(< 8.9)
Standard DIN EN ISO 20643
Uncertainty of measurement of
vibration total value a
hv
m/s
2
(ft/s
2
)
0,5
(1.6)
*
These measurements were obtained when the device was operated freely suspended in the air at a distance of 1
meter.
**
The rated power is the active power consumed during nominal operation.
***
Cable length: including plug as far as inverter.