Operator`s manual

Maintenance GV 7000A/7003A
wc_tx000274gb.fm 30
4.9 Troubleshooting
Problem / Symptom Reason / Remedy
If engine doesn't start, check
that:
Engine switch is on "Start".
Fuel valve is open.
Fuel tank has fuel.
Choke lever is in correct position. Choke should be
closed when starting a cold engine.
All loads are disconnected from generator.
Spark plug is in good condition.
Spark plug cap is tight.
Engine oil level is adequate.
If engine starts but there is no
power at receptacles, check
that:
Circuit breaker is closed.
Wiring from generator to receptacles is tight.
If engine starts but runs errati-
cally, check:
Condition of air filter.
Condition of spark plug and plug cap.
Freshness of fuel.