Operator`s manual
GV 7000A/7003A Operation
wc_tx000273gb.fm 23
3.9 To Start
See Graphic: wc_gr001299
3.9.1 Disconnect all loads from the generator and place main circuit breaker
in open position (e2) (GV 5003A, GV 7003A).
3.9.2 Open fuel valve (a).
Note: If engine is cold, move choke (b) to closed position—pull out.. If
engine is hot, set choke to open position—push in.
3.9.3 Turn engine switch to "ON" (c1) and pull starter rope (d).
Note: If the oil level in the engine is low, the engine will not start. If this
happens, check oil level and add oil as needed.
3.9.4 Open choke as engine warms (b).
3.9.5 Place main circuit breaker in closed position (e1) (GV 5003A, GV
7003A). Allow the engine to warm up for a few minutes before
attaching loads.
3.10 To Stop
See Graphic: wc_gr001299
3.10.1 Turn off and disconnect all tools and appliances attached to the
generator.
3.10.2 Turn engine switch to “OFF” (c2).
3.10.3 Close fuel valve (a).
Note: To stop engine quickly in an emergency, turn engine switch to
“OFF” (c2).