2.12 Grounding the Generator
Location
The ground lug (d) is located to the right of the DC terminals.
Function
This ground connection is used for electrically grounding the generator when 
necessary to comply with the National Electrical Code and other federal, state, and 
local regulations. For grounding requirements in your area, consult with a qualified 
electrician, electrical inspector, or local agency having jurisdiction over electrical 
compliance.
 If the generator is used at a construction site, there may be additional 
regulations which must be observed.
 In some areas, generators are required to be registered with local utility 
companies.
Connection
Connect the ground lug to a good earthen ground for proper operating safety in 
compliance with NEC and local standards. The following options may be used:
 Connect the ground lug to a grounding spike (w) and drive the grounding spike 
into the earth.
 Connect the ground lug to an existing grounded conductor.
wc_gr006664