Product Manual

wc_tx004575gb.fm
50
Troubleshooting GP
6 Troubleshooting
Problem / Symptom Reason / Remedy
If engine doesn't start, check that:
Engine switch is on “Start”.
Fuel valves under fuel tank and on engine are open.
Fuel tank has fuel.
Choke lever is in correct position. Choke should be closed when
starting a cold engine.
All loads are disconnected from generator.
Spark plug is in good condition.
Spark plug cap is tight.
Engine oil level is adequate.
If engine starts but there is no
power at receptacles, check that:
Circuit breaker is closed.
Connector from generator to control panel is tight.
If engine starts but runs erratically,
check that:
Hose routing from the fuel tank to the engine is correct. For
proper operation, the hose must run through the bushing in the
lifting bracket. Refer to the Parts Book for illustration.
If the GFCI trips when a load is
connected, check that:
The connected equipment may be wired incorrectly or faulty.
Contact equipment supplier.
See section Determining Power Requirements.