Loads such as submersible pumps and air compressors require a
very large force to start. They need as much as 3–5 times the wattage
stated on the nameplate in order to start.
If the wattage is not given for a particular tool or appliance, it can be
calculated by multiplying its voltage and amperage requirements:
Single Phase: VOLTS x AMPS = WATTS
Three Phase: VOLTS x AMPS x 1.732 x 0.8 = WATTS
2.3 Recommended Battery (GPS only)
This generator is shipped without a battery. The recommended battery
to be used is:
Battery Type 50-N18L-A
Voltage 12 V
Capacity 20 A/h
L x W x H 206 x 90 x 164 mm