Operator`s manual

Maintenance G 25
76 wc_tx001046gb.fm
7.3.1 To access the main menu, press the right arrow button (1) on the
keypad (g).
Note: If there are active alarms or pre-alarms, press the left arrow button (4)
three times to access the main menu.
7.3.2 Using the up/down arrow buttons (2,3), select SETTINGS and press
the right arrow button.
7.3.3 Select SYSTEM PARAMETERS. Press the right arrow button (1).
7.3.4 Select SYSTEM SETTINGS. Press the right arrow button (1).
7.3.5 Select MAINT RESET. Press the check mark button (5).
7.3.6 If necessary, enter your password. (See Entering Passwords for more
information.)
7.3.7 When prompted, select YES and press the check mark button.
7.3.8 Exit by repeatedly pressing the left arrow button (4) until the LCD
panel display returns to monitoring status.
7.4 Lubricating the Engine
Checking oil
Check engine oil daily before starting engine.
Do not operate engine if oil level is below ADD mark on dipstick.
Always keep oil level within the crosshatch pattern or “full” mark
on dipstick.
Change oil after first 50 hours of operation and every 250 hours
thereafter. Refer to the engine manufacturer’s Operator’s Manual
for lubrication specifications.
WARNING
Burn hazard. Engine, engine oil, muffler, and exhaust pipes become extremely hot
during operation.
f Stop the engine and allow the machine to cool before checking the oil or replac-
ing the engine oil or oil filter cartridge.