Operator`s manual
Operation G 25
48 wc_tx001045gb.fm
4.19 Engine Monitoring
With the engine start switch set to “RUN/START” or “REMOTE
START”, engine information will be continuously displayed on the
bottom line of the LCD panel.
OIL —Displays engine oil pressure. The gauge registers oil
pressure between 0–100 psi. Normal operating pressure is between
60–80 psi. If oil pressure drops below 15 psi, the engine will
automatically shut down.
FUEL —Indicates the relative fuel level in the fuel tank. If fuel
level drops to 5% the engine will automatically shut down.
TEMPERATURE —Displays the temperature of the engine's
coolant. If the coolant temperature gets too high, the engine will
automatically shut down.
BATTERY —This gauge measures the engine starting battery
voltage. A normal reading is 13.5–14.5V. If the gauge falls much
below or above these values, the engine charging system should be
checked. With the engine switch set to “REMOTE START” and the
generator in stand-by mode, actual battery voltage is displayed.
ENGINE HOURS—The engine running hours are displayed on the
hour meter. Engine hours are accumulated only while the engine is
actually running.
SENDER FAILURE - Indicates that the coolant temperature sensor,
fuel lever sender, speed signal source, or the oil pressure sensor has
failed. This fault will not be displayed unless the fault has occurred;
also, this fault will not shut down the machine. If all speed signal
sources fail, the machine will shut down.
Engine Fault Set Points
Fuel Level = 5%
Low Oil Pressure = 1 bar (15 psi)
High Temperature = 105°C (221°F)
Underspeed = 55Hz (1650 rpm)
Overspeed = 66Hz (1980 rpm)
Overcrank = Three 10-second crank/rest cycles