Operator`s manual
ALWAYS:
Keep connection devices free of sand and dirt.
Rinse in clear water before and after each use.
Inspect seals and gaskets before and after each use.
Reinstall caps or protective covers after each use.
Unlock the Cam-Lock by swinging the locking arms
outward. Insert the male fitting and lock by simultaneously
swinging the arms inward as shown.
PUREHEAT QUICK-CONNECT AND CAM-LOCK CARE AND MAINTENANCE
NEVER:
Drop onto a hard surface such as concrete.
Drive over with any size vehicle.
Attempt to use damaged connection devices.
Attempt to use when contaminated with soil,
vegetation or any
petroleum product.
Attempt to use with damaged or worn seals or
gaskets.
Lubricate with petroleum products.
1
RINSE
VITON GASKET
P/N P100-352
MALE QUICK CONNECT
(P/N M100-258)
FEMALE QUICK CONNECT
(P/N M100-259)
MALE CAM-LOCK
P/N M100-700
FEMALE CAM-LOCK
P/N M100-728
MALE QUICK CONNECT
(P/N M100-258)
2
PUSH LOCKING
RING BACK
3
INSERT MALE
QUICK-CONNECT,
RELEASE LOCKING RING
V. 2, Rev. 09/01/06
B - 11
© 2006 Ground Heaters, Inc.