Operator`s manual
PUREHEAT MAIN CONTROL PANEL
EXTERIOR COMPONENT FUNCTION AND IDENTIFICATION
DOOR COMPONENTS
BREAKER 1 CURVE 10 15 AMP. (P/N E100-354):
Provides ON and OFF power control and circuit protection for electrical circuit one.
BREAKER 2 CURVE 10 20 AMP. (P/N E100-123):
Provides ON and OFF power control and circuit protection for electrical circuit two.
LINE 1 GFI (P/N E100-093):
A Ground Fault Circuit Interrupter (GFI) which provides operator protection for electrical circuit one.
LINE 2 GFI (P/N E100-093):
A Ground Fault Circuit Interrupter (GFI) which provides operator protection for electrical circuit two.
HOUR METER (P/N E100-096):
A meter to record total hours of use. The Hour Meter functions only when the BURNER Switch is turned ON and does
not reflect actual
burner run time.
TEMPERATURE CONTROL (P/N E100-084):
Provides ON and OFF control of the Burner based on set-point (desired temperature) as well as primary high and low temperature limit
functions. The digital display panel indicates the Heat Transfer Fluid (HTF) temperature in red, the set-point (desired temperature) in
green and output indication (demand for heat) by illuminating the C1 light in the upper left of the display panel. Set-point is adjusted using
the UP and DOWN arrow Keys located below the display panel.
BURNER FAULT LAMP (P/N E100-353):
Indicates the Burner Control has sensed flame failure and has entered BURNER FAULT mode. All Burner functions are disabled during
BURNER FAULT mode except for the Inline Fuel Heater (oil burner only) which is powered directly by the BURNER Switch.
LOW LEVEL FAULT LAMP (P/N E100-353):
Indicates that the Low Level Shut Down Device sensed an HTF loss and has entered LOW LEVEL FAULT mode. All Burner and Pump
functions are disabled except for the Inline Fuel Heater (oil burner only) which is powered directly by the BURNER Switch.
HTF FILL SWITCH (P/N E100-230):
Used to operate the Pump during a LOW LEVEL FAULT to effect re-filling of HTF.
PUMP SWITCH (P/N E100-101):
Provides operation and control of the HTF Pump.
BURNER SWITCH (P/N E100-101):
Provides ON or OFF power control to the Burner.
REWIND MOTOR SWITCH (P/N E100-101):
Provides ON or OFF power control to the Rewind Motor.
CAB LIGHT SWITCH (P/N E100-101):
Provides ON or OFF power control to the Interior Cab Light.