Operator`s manual

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 6
6- 2 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06
If problem is not resolved by performing the above steps, call your Ground Heaters Distributor for assistance.
Symptom Possible Cause Corrective Action Refer To
Improper switch position or
protective function action.
Verify both
MAIN BREAKERS are ON.
Verify both
GFIs are reset.
Verify LOW LEVEL FAULT light is not
lit.
Verify HTF level is between MIN and MAX
level.
Verify LOW LEVEL SHUTDOWN DEVICE
is RESET.
Appendix
A-2
Section 2
Appendix
A-18
Burner motor will
not start
( . . .continued)
Burner Safety is tripped as
indicated by DIAGNOSTIC light
on burner control.
Reset burner safety.
Appendix
A-10 or A-13
No fuel.
Verify fuel supply is adequate.
Verify both
fuel line Quick-Connects are
connected (oil burner).
- - - - - - -
Section
4.2.1.1
Burner safety
trips (no flame).
Insufficient voltage for ignition.
Have an electrician verify voltage at
control panel is 110 volts (min.) while
attempting
to start burner.
Ensure power cords are at least 10
gauge wire and 100 ft (30.5 m) in
length.
Verify power cords are supplied by
separate 20 amp 120 volts AC 60 Hz
electrical power circuits.
- - - - - - -
Burner safety
trips
(flame occurs).
Control not sensing flame.
Call your Ground Heaters
Distributor.
- - - - - - -
Heat exchanger
blower will not
start.
No electrical power.
Thermostat or speed selector
setting incorrect.
Verify 120 volts AC to heat exchanger.
Set thermostat above room temperature.
Set speed selector to desired fan speed.
- - - - - - -
Brake not fully released.
Fully release hose reel brake.
Section
2.6.3
Rewind motor is too cold
(rewind motor may not start if
below 0ºF [-18°C]).
Warm rewind motor.
- - - - - - -
Hoses will not
rewind.
Faulty foot pedal.
Call your Ground Heaters Distributor.
- - - - - - -