Operator`s manual
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4
4- 4 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06
4.2.2.1 Installation
(Refer to Appendix A-24)
1. Remove the trailer enclosure lower panel located
below the trailer's left side door adjacent to the
fender (to provide unrestricted access to the Burner
mounting plate on the Pureheat™ Hydronic Air
Heater). (Photo 4-3)
2. Verify that the gasket is properly positioned on the
mounting flange and Burner blast tube.
3. Insert the blast tube into the hydronic heater Burner
mounting plate and attach with the four bolts which
have been supplied. The Burner should be oriented
with the Power Flame Model JR30A-12 label
oriented right side up.
4. Using the supplied 1¼ in. x
5
/
16
in. bolts, washers and nuts, install the Burner support bracket on
the trailer floor below the Burner. Extend the adjusting rod such that the square pad firmly
contacts the Burner support flange. Tighten the jam nut to keep the support rod from backing off.
5. Reinstall the enclosure panel next to the fender.
6. Attach the 3-pin Quick-Connect Burner power cord leading from the Main Control Panel to the
connection socket located just behind the blue Honeywell™ Burner control.
7. Attach the gas train at the pipe union (secure to gas train mounting bracket), with the horizontal
portion of the gas train extending toward the tongue of the trailer. Do
not use pipe dope on this
joint
.
8. Attach the 2-pin Quick-Connect power cord leading from the Burner control to the electrical
junction box mounted on the gas train.
9. Connect the 90º end of the braided pilot gas line to the fitting provided on the left side of the gas
train. do
not use pipe dope on this joint.
10. Verify that the two ball valves and the pilot valve on the gas train are turned OFF.
11. Attach the 36 in. x ¼ in. poly vent hose to the main gas pressure regulator vent and route it
outside through the 5 in. (127 mm) square access panel in the floor.
12. Attach the 17 in. x ¼ in. poly vent hose to the pilot pressure regulator and route it outside through
a slot in the trailer floor along the left side of the trailer.
13. Attach the NG or LP gas supply line to the main gas inlet fitting at the left side of the gas train.
This gas line should enter the trailer through the 5 in. (127 mm) square access panel in the floor
of the trailer.
4.2.2.2 Setup
1. Open the top Burner air inlet damper 100 percent. The bottom air inlet damper should be
completely closed. This initial setting will be fine tuned later.
2. Follow procedures located in Sections 3.1.1.1 through 3.1.1.4 to complete Burner adjustment.
Do not turn on the gas at this time.
NOTE: The gas supply line must be sized such that it is capable of providing a minimum of 860 CFH NG
(or 344 CFH LP vapor) at 5 to 14 in. water column pressure.
!
4-3