2.5 OPERATING WITH OPTIONAL ACCESSORIES
The Pureheat has the capability to operate with up to Twenty (20) 750 ft (228 m) Accessory Hose Loops
using One (1) Booster Pump, Five (5) Hose Handling Systems 3004 (HHS3004), Five (5) 4-Port Remote
Manifolds and One (1) Auxiliary Pump Panel.
2.5.1 Using Three HHS3004 with Booster Pump for Thawing Applications
(Refer to Appendix B-6.)
Thawing applications require the use of Three (3) HHS3004s with Twelve (12) 750 ft (228 m) Accessory
Hose Loops of 5/8 in. ID Heat Transfer Hose (HTH), One (1) optional Booster Pump, Three (3) 4-Port
Remote Manifolds and One (1) Auxiliary Pump Panel.
1. Install the optional Booster Pump and Auxiliary Pump Panel as directed in Section 2.8,
CONNECTING/DISCONNECTING OPTIONAL BOOSTER PUMP.
2. Place the Three (3) HHS3004s and Three (3) 4-Port Remote Manifolds spaced appropriately on the
jobsite for thawing application.
3. Connect the Three (3) 4-Port Remote Manifolds to the 5-Port On-Board Manifold as directed in Step
2.2.7, Deployment of Circulation Hoses.
4. Connect the Accessory Hose Loop 1 Female QC to one of the available 4-Port Remote Manifold
Discharge Male QCs.
5. Remove the Accessory Hose Loop 1 from the HHS3004 Reel and place at job site for thawing
application. The QCs joining Accessory Hose Loop 1 and Accessory Hose Loop 2 will be exposed
when nearing the end of Accessory Hose Loop 1.
6. Once the QCs have been exposed, separate Accessory Hose Loop 1 and Accessory Hose Loop 2.
Connect the Accessory Hose Loop 1 Male QC to one of the available 4-Port Remote Manifold Return
Female QCs.
7. Connect the Accessory Hose Loop 2 Female QC to one of the remaining 4-Port Remote Manifold
Discharge Male QCs.
8. Remove the Accessory Hose Loop 2 from the HHS Reel and place at job site for thawing application.
The QCs joining Accessory Hose Loop 2 and Accessory Hose Loop 3 will be exposed when nearing
the end of Accessory Hose Loop 2.
9. Once the QCs have been exposed, separate Accessory Hose Loop 2 and Accessory Hose Loop 3
QCs. Connect the Accessory Hose Loop 2 Male QC to one of the available 4-Port Remote Manifold
Return Female QCs.
10. Repeat Step 4 through Step 9 for the remaining Accessory Hose Loop 3 and Accessory Hose Loop 4
of the HHS3004.
11. Repeat Step 4 through Step 10 for the remaining Two (2) HHS3004s.
12. Power up the Main Control Panel as directed in Section 2.3, INITIAL POWER UP and start the
optional Booster Pump after starting the Main Pump.
The Booster Pump must
be connected to the Auxiliary Pump Panel to maintain low
HTF level protection. Operating the Booster Pump without low HTF level protection
could lead to complete loss of system HTF and HTF Pump failure.
2.5.2 Using Five HHS3004 with Booster Pump for Curing and Frost Prevention Applications
(Refer to Appendix B-7 and B-8.)
Curing and Frost Prevention applications require the use of Five (5) HHS3004 with Twenty (20) 750 ft
(228 m) Accessory Hose Loops of 5/8 in. ID Heat Transfer Hose (HTH), One (1) optional Booster Pump,
Five (5) 4-Port Remote Manifolds and One (1) Auxiliary Pump Panel.
1. Install the optional Booster Pump and Auxiliary Pump Panel as directed in Section 2.8,
CONNECTING/DISCONNECTING OPTIONAL BOOSTER PUMP.
!