Repair manual
Troubleshooting the Burner Cub 200/300
50 ghi_tx001207gb.fm
Continued from the previous page.
10.With the machine on, check the continuity between the same terminals of the air
pressure switch.
Is there continuity?
11.Turn the machine off.
12.Reinstall the wires.
Result
The air pressure switch has now been checked.
If the problem has not been resolved, leave the machine disassembled and
continue with the next topic. Otherwise, reassemble the machine.
Yes ____ No ____
The air pressure switch is OK. The air pressure switch has failed. Shut
down the machine and replace the air
pressure switch.