Troubleshooting the Burner Cub 200/300
46 ghi_tx001207gb.fm
6.4 Checking Output Voltage from the Control Board
Requirements
Multimeter
Procedure
Perform the procedure below to check output voltage from the control board for the
fuel system.
1. Start this procedure with the machine disconnected from the power supply.
2. Remove the screws (a) that hold the control panel and pull the control panel
from the machine.
3. Remove the cover (b) from the control panel.
4. Connect the machine to the power source.
5. Turn the machine on. If the machine is in a fault condition, press the RESET (c)
button on the control panel.
This procedure continues on the next page.
WARNING
Electric shock hazard. High voltage exists inside the control panel when the power
cord is plugged into a power supply. Electric shock can cause serious injury or
death.
f Use extreme care and appropriate arc flash avoidance techniques when mea-
suring live, high voltage.