Repair manual
Cub 200/300 Troubleshooting the Burner
ghi_tx001207gb.fm 39
6.1 Checking the Ignition Transformer
Requirements
Fuel solenoid disconnected
Procedure
Perform the procedure below to check the ignition transformer.
1. Begin this procedure with the power supply disconnected.
2. Open the access panel (a).
3. Locate the fuel solenoid (b) and disconnect it.
4. Loosen the wingnut (e) and open the air lock as far as possible.
5. Connect the power supply.
6. Turn the machine on and observe the spark between the electrodes (f).
Is a good, strong spark visible?
This procedure continues on the next page.
Yes ____ No ____
The ignition transformer is OK. Continue.