Operator`s manual

HI 110 / 200 / 300 Technical Data
ghi_td000400gb.fm 55
Model
HI 300D
HI 300HD D
Units
Heat input BTU/hr 293,982 293,982
Heat output BTU/hr 245,475 245,475
Air flow cfm 2531 2531
Fuel consumption L (gal)/hr 8 (2.12) 8 (2.12)
Fuel nozzle size L/hr (gph) 5.7
(1.50) (80W)
5.7
(1.50) (80W)
Efficiency % 83.5 83.5
Noise level at 1 m dB (A) 75 75
Power requirement VAC/Hz 120/60 120/60
Electrical current Ampere 15 15
Weight (no fuel) kg (lb) 129.3 (285) 177.8 (392)
Height mm (in.) 1143 (45) 1245 (49)
Length mm (in.) 1740 (68.5) 2159 (85)
Width mm (in.) 700 (27.5) 864 (34)
Flue diameter mm (in.) 152.4 (6) 15.2 (6)
Fuel tank capacity L (gal) 134.8 (35.6) 216.1 (57.1)
Fuel pressure psi 200 200
Air band setting
Diesel fuel (production)
Diesel fuel (max. efficiency)
Winter blend (production)
Winter blend (max. efficiency)
Number
4.0
3.2
6.8
3.4
Number
4.0
3.2
3.5
3.2