Operator`s manual

Maintenance Cub 200/300/300 HD
wcghi_tx000721gb.fm 44
5.15 Troubleshooting
Issue Ref Description
The burner does not start The remote thermostat
or thermostat plug is not
inserted correctly.
Faulty cable or power
supply
The over temperature
limit has tripped
The burner is in lock-out
mode.
Insert the remote
thermostat or thermostat
plug.
Check cable and power
supply
Call Ground Heaters,
Inc. for service
assistance.
Press the reset button.
The burner starts, the flame
does not ignite, the unit
locks out
No fuel
Worn burner nozzle
Faulty electrodes
Cad cell detecting
external light.
Cad cell defective
Burner control defective
Fill fuel tank
Replace burner nozzle
Replace electrodes
Check the Cad cell
enclosure
Contact Wacker Neuson
Product Support
The burner starts, flame
ignites, but the unit locks
out
Incorrect fuel pressure
Worn burner nozzle
Incorrect air lock setting
Cad cell defective
Burner control defective
Increase fuel pressure
Replace burner nozzle
Re-adjust air lock setting
Contact Wacker Neuson
Product Support
The burner ignites but the
performance is poor
Worn burner nozzle
Clogged fuel filter
Air leaks in the fuel lines
Insufficient oil pressure
Replace burner nozzle
Replace the fuel filter
Inspect the lines for
leaks; replace if
necessary
Contact Wacker Neuson
Product Support
Black smoke from vent pipe Insufficient combustion
air
Insufficient ventilation air
Contact Wacker Neuson
Product Support
The machine stops due to
pressure switch fault
Overheat condition
Faulty pressure switch
Contact Wacker Neuson
Product Support