5.10 Inspecting the Flame Head
See Graphic: wcghi_gr004028
To inspect the flame head, carry out the following procedure:
5.10.1 Remove the burner assembly. See section Removing and Installing
the Burner Assembly.
5.10.2 Mark the location of the air lock sleeve (c) with a pencil.
5.10.3 Loosen the wing nut (b).
5.10.4 Loosen the four screws (a) that secure the flame head (d).
5.10.5 Turn the flame head (d) counter-clockwise and remove.
5.10.6 Inspect the flame head (d) for the following:
Wear. Replace if necessary.
Cleanliness. Clean the flame head if necessary.
Thermal stress. Replace if necessary.
5.10.7 Re-install the flame head (d).
5.10.8 Position the air lock sleeve (c) at the marked location.
5.10.9 Tighten the winged (b).
5.10.10 Tighten the four screws (a).
5.10.11 Re-install the burner assembly. See section Removing and Installing
the Burner Assembly.