Repair manual
CRT Repair Steering and Pitch Control
wc_tx000584gb.fm 121
7.26 Error Code 414—Control Board Overtemperature
If a low battery condition occurs, shutdown the machine.
• Inspect the battery and the wiring harness.
• Remove any corrosion from the battery terminals.
• Inspect the wiring for the actuator motors at the control panel.
Remove any corrosion from the wiring.
• Check the 50A and 70A maxi-fuses. Remove any corrosion from
the fuse connectors.
• Load test the battery. Recharge or replace the battery as needed.
The battery must be above 11VDC.
• Test the alternator output. The alternator is rated at 65A. Replace
the alternator if needed.