Repair manual

10 Maintenance
105 Miscellaneous
Pry out the stop pin (7) with the combination wrench (8) far enough, as shown
in the figure, so that you are able to turn the protective hood (10).
Note: Once the stop pin (7, Fig. page 104) has been pulled out, the rotary
stop (7) is deactivated. This makes it possible to turn the protective
hood (10) beyond the rotary stop (7).
Unscrew the handle (9) and turn the protective hood (10), as shown in the fig-
ure.
Detach the V-belt (11) and remove the cutting attachment.
Press the cutting attachment (12) to the outer position against the gear arm
receptacle.
Guide the V-belt (13) over the V-belt pulley (14).