Product Manual
Table Of Contents
- 1 CALIFORNIA Proposition 65 Warning
- 2 Preface
- 3 Introduction
- 4 Security
- 4.1 Policy
- 4.2 Proper use
- 4.3 Structural changes
- 4.4 Areas of responsibility of the operator
- 4.5 Operator responsibilities
- 4.6 Personnel qualification
- 4.7 Residual dangers
- 4.8 General safety instructions
- 4.9 Specific safety instructions - Vibratory rammer AS
- 4.10 General safety instructions – fuel, lubricants and coolants
- 4.11 Maintenance
- 4.12 General safety instructions - Rechargeable battery (accessories)
- 4.13 General safety instructions - Battery charger (accessories)
- 4.14 Personal Protective Equipment
- 4.15 Behavior in dangerous situations
- 5 Safety and information labels
- 6 Setup and function
- 7 Components and operator's controls
- 8 Transport
- 9 Storage
- 10 Operation and use
- 11 Maintenance
- 12 Troubleshooting
- 13 Disposal
- 14 Disposal
- 15 Accessories
- 16 Technical data
- 17 Glossary
16 Technical data
100_0201_td_0002.fm 43
16.3 Battery charger
16.3.1 Extension cable
The following points must be observed:
Only use approved extension cables.
Data about the model designation and voltage of this machine is located on the nameplate.
The necessary stranded conductor cross-section can be found in the following table.
Designation C48/4
Item number 5100006221
Rated voltage V 230 (90 – 265)
Kind of current (input) AC 1~
Rated current A <3
Rated frequency Hz 50–60
Kind of current (output) Direct current +/-
Output current A 4 +/-0.5
Max. output voltage V 57.6
Length mm 190
Width mm 145
Height mm 65
Weight kg 2.0
Power cable mm 1,500
Power cable mm 1,800
Class rating II
Protection rating IP54
Storage temperature range °C -30–+50
Operating temperature range °C 0 - +45
WARNING
Warning of electrical voltage!
Serious injury due to electric shock.
Check power cable and extension cable for damage.
Only use extension cables whose grounded conductor is connected to the plug and
coupling - only for machines of class rating I + III, see chapter Technical data.
Machine type Voltage
[V]
Extension
[m]
Stranded conductor
cross-section
[mm
2
]
C48/4 230 < 150 1.5
C48/13 230 < 150 1.5