Product Manual

Table Of Contents
11 Maintenance
34 100_0201_mt_0002.fm
Oil change – AS50e
1. Remove dirt accumulation within the range of the oil level glass.
2. Screw on the oil level glass. Clean the thread on the inspection glass and wrap with Teflon tape.
3. Tilt the vibratory rammer backward until it rests on the control handle and the drain the used oil into
a suitable reservoir.
4. Tilt the vibratory rammer forward and secure in this position.
5. Fill oil through the opening in the inspection glass in the housing. For the oil specification, see chapter
Technical Data.
6. Screw the inspection glass back on, but do not tighten.
7. Stand the vibratory rammer upright to check the oil level.
8. If necessary, top off the oil until the inspection glass is 1/2 to 3/4 filled.
9. Then tighten the inspection glass. The tightening torque is 9 Nm.
10.Wipe the area of the oil level glass with a clean cloth.
NOTE
Used oil must be disposed of according to the applicable local environmental protection
regulations.
NOTE