Product Manual
13 Faults
30 100_0101_ts_0010.fm
13 Faults
13.1 Troubleshooting table - FUflex Inverter
13.2 Troubleshooting Table - Bodyguard
®
DANGER
Danger to life from unauthorized troubleshooting.
If faults occur with this machine that are not described in this manual, contact the
manufacturer. Do not eliminate the faults independently.
Fault Cause Remedial measure
The control lamp illuminates red.
Mains voltage interrupted.
Incorrect mains voltage.
The inverter starts automatically as
soon as the correct mains voltage
is present (again).
The control lamp flashes red. Defect in the vibrator head. Have the machine repaired.*
Control lamp flashes red twice. Inverter shut down due to
excessive temperature.
1. Allow inverter to cool down.
2. Carry out reset:
Switch machine off and on.
Control lamp blinks 3 times red (for
a short time).
The Bodyguard
®
has switched off
the machine.
Have the machine repaired.*
No Bodyguard
®
present.
*
Have this work performed by the service department of the Wacker Neuson contact partner.
Fault Cause Remedial measure
Indicator light doesn't light up.
Mains voltage is applied.
The Bodyguard® turned off the
machine.
Machine error.
1. Pull plug out of plug receptacle.
2. Check connection cable for
damages – replace in case of
damage.*
3. Insert plug into plug receptacle.If
the fault is not remedied, have
the machine repaired.*
Water in the converter.
Defect in the oscillating body.
Have the machine repaired.*
Indicator light doesn't light up. No mains voltage. 1. Pull plug out of plug receptacle.
Check connection cable for
damages – have machine repaired
in case of damage.*
Bodyguard® defective. Have the machine repaired.*
Plug defective.
Indicator light defective.
Indicator light does not go out with
function testing.
Test button or Bodyguard®
defective.
Have the machine repaired.*
*
Have this work performed by the service department of your Wacker Neuson contact partner.