Product Manual
9 Quickflex Coupling Assembly
100_0101_ot_0003.fm 21
9.3 Assemble IRflex vibrator head and FUflex inverter
1. Clean the flat-faced sealing surfaces of the Quickflex coupling and inspect for damage.
2. Stick the IRflex vibrator head together with the FUflex inverter.
Align the halves of the coupling with the checkmark.
Plug in linear manner until resistance is first recorded.
Continue pressing until the stop is reached and the locking nut (IR side) engages in the coupling
thread (FUflex side).
3. Screw the Quickflex coupling together as tightly as possible.
Item Designation Item Designation
1 FUflex inverter 3 IRflex vibrator head
2 Quickflex coupling, Locking nut (IR side)/
coupling thread(FUflex side)
NOTICE
The flat-faced sealing surfaces of the Quickflex coupling are soft components, which are
co-responsible for IP protection.
The inside of the Quickflex-coupling must be clean and dry before connecting.
Item Designation
1 Checkmark
NOTICE
The lock screw cannot be screwed in until the final stop is reached.
Item Designation
1 Retaining screw and protective cap
1
2
3
1
1