User`s manual

Chapter 5, Operating Instructions: Operating the Standard Machine
E.H. Wachs Company Part No. 06-150-520-MAN, Rev. 0-0607 31
Figure 5-17. The hydraulic autofeed mechanism is
shown. The feed can be driven using a wrench on the
hex end of the clevis.
OPERATING THE STANDARD MACHINE
Follow the instructions in this section to set up and operate
the standard Goliath Guillotine (configured without auto-
clamp or topside controls).
Connecting the Hoses
1.
Connect the hydraulic pressure hose to the pressure
side connector (with the flow bypass valve) on the
saw.
There is no flow/
speed control on
the standard Goli-
ath. If your HPU does not
have speed control, call E.H.
Wachs Company to request
an optional flow control valve
assembly.
2.
Connect the return hose to the return side connector on
the saw.