Installation Sheet
Phone (800) 526.2588
Fax (800) 526.2585
44 Harbor Park Drive
Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Avenue
Ontario, CA 91760
2
INSTALLATION INSTRUCTION
Bath Lighting
WS-73117/WS-73123
3000K3500K 2700K
(WS-73117)
5
1
2
"
6
1
2
"
(WS-73123)
2
3
8
"
1
5
8
"
1
3
8
"
G
ND
1
3
8
"
1
3
4
"
Ø4"
Conversion Plate
1
4
2
"
7"(WS-73123)
6"(WS-73117)
5
1
8
"
3
1
8
"
A
B
A
D
E
C
Switch
Box Screw
Mounting
Back Plate
Black Wire
White Wire
Wire Connector
Switch Box
Bare Copper
Ground Wire
Wire Connector
Bare Copper
Ground Wire
Junction
Box
Mounting
Screw
Mounting Ring
Conversion
Plate
Black Wire
White Wire
Junction
Box Screw
Assembly
Screw
MOUNT ON JUNCTION BOX
Switch
Switch
B
Mounting
Screw
Fig.1 MOUNT ON SWITCH BOX
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the xture.
4. The lamp can switch between three color temperatures (2700K-3000K-3500K), which can be adjusted to your preference with the switch in
the canopy (Fig.3).
MOUNT ON SWITCH BOX
Secure the mounting back plate to the switch box using the screws provided with the switch box.
MOUNT ON JUNCTION BOX
(i) Secure the mounting ring (E) to the junction box using standard junction box screws that comes with the junction box.
(ii) Secure the mounting back plate and conversion plate (D) to the mounting ring with assembly screw (C).
NOTE
: (i) using any other non-original-manufacturer provided junction box screw may result in safty issue;
(ii)
The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the xture’s wires to junction box wires as shown (Fig. 2). Make sure that all wire connectors (A) are secure. If your outlet box has
a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the back
plate using the GND screw provided. After wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION (Fig. 1)
7. Secure the
xture to the mounting back plate using the mounting screw (B).
Mounting
Back Plate
Fig.2 Wiring
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Mounting RingMounting Back PlateFig.3 Switch