INSTALLATION INSTRUCTION
W Track Recessed 277V Flange
WHT4-RT, WHT8-RT, WHT12-RT
C: SUSPENSION MOUNTING
•  Slide or snap the hanger clips (WMT-RT) onto the track, and 
space the clips evenly along the track length. 
•  Secure the bolt and make sure the hanger clips tightly hook 
in the track groove. 
•  Assemble the stem or cable suspender (refer to WT/WHT 
track suspension system) to the hanger clips. Level track 
and secure to building structure.
•  Recommended: two clips for 4’ track, three clips for 8’ track, 
and four clips for 12’ track. Always use more than one clip 
for each track length. Additional clips may be added for 
more support. 
Feed options
Live End Connector can be fed directly from above 
using a 1/2 inch or 3/4 inch electrical connector.
•  Make sure power is o before wiring.
•  Note the polarity indicator of the track and accessories.
•  Remove cover and save.
•  Remove knockout in top plate.
•  Secure conduit by conduit connector (1/2 or 3/4 size 
recommended) to top plate and lock the nut.
•  Pass wires (12AWG) through conduit and connector. 
Cut and strip each end of the wire, then a single conductor 
is clamped directly under the head of the screw when it is 
tightened. The single conductor is bent around the screw in 
a 3/4 loop, insert the wires to the corresponding terminals 
(see g. below) and secure tightly with a screw.
•  Secure the track to the ceiling (see mounting options on 
previous page).
•  Replace the cover.
•  Insert the spline and secure to the track with two screws.