Installation & Assembly

WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2014
INSTALLATION INSTRUCTION
W Track Recessed 277V Flange
WHT4-RT, WHT8-RT, WHT12-RT
C: SUSPENSION MOUNTING
Slide or snap the hanger clips (WMT-RT) onto the track, and
space the clips evenly along the track length.
Secure the bolt and make sure the hanger clips tightly hook
in the track groove.
Assemble the stem or cable suspender (refer to WT/WHT
track suspension system) to the hanger clips. Level track
and secure to building structure.
Recommended: two clips for 4’ track, three clips for 8’ track,
and four clips for 12’ track. Always use more than one clip
for each track length. Additional clips may be added for
more support.
Feed options
Live End Connector can be fed directly from above
using a 1/2 inch or 3/4 inch electrical connector.
Make sure power is o before wiring.
Note the polarity indicator of the track and accessories.
Remove cover and save.
Remove knockout in top plate.
Secure conduit by conduit connector (1/2 or 3/4 size
recommended) to top plate and lock the nut.
Pass wires (12AWG) through conduit and connector.
Cut and strip each end of the wire, then a single conductor
is clamped directly under the head of the screw when it is
tightened. The single conductor is bent around the screw in
a 3/4 loop, insert the wires to the corresponding terminals
(see g. below) and secure tightly with a screw.
Secure the track to the ceiling (see mounting options on
previous page).
Replace the cover.
Insert the spline and secure to the track with two screws.