Current Limiter - Surface Mount W Track
WEDL, WHEDL, WEDR, WHEDR
B: INSTALLING CURRENT LIMITER TO 4” SPACE OCTAGONAL JBOX
Note: Center of track must coincide with center of J-Box
1. Remove appropriate knockout in Top Plate , and feed 3/8” or 1/2” Conduit and Supply leads into Top Plate. Fasten Conduit
to top plate.
2. Feed Supply wires through knockout hole. Attach wires per electrical connection instructions.
3. Attach Track to Current Limiter. Be sure to check for proper polarity between track and switch. Also ensure all 5 contact plates
are properly inserted into each individual track circuit.
4. Replace Cover.
5. Secure the track to the ceiling.
A: INSTALLING POWER LIMITER TO CONDUIT OR GRID RUNNER CEILING :
1. Remove Cover.
2. Remove appropriate knockout in Top Plate or Plastic Crust, and feed 3/8”or 1/2” Conduit and Supply leads into Top Plate or
Plastic Crust. Fasten Conduit to top plate or Plastic Crust.
3. Attach wires per electrical connection instructions.
4. Attach Track to Current Limiter. Be sure to check for proper polarity between track and switch. Also ensure all 5 contact plates
are properly inserted into each individual track circuit.
5. Replace Cover.
6. Secure the track to the ceiling.
Conduit Connector
(3/8” or 3/4”)
Conduit
Electrical Wire (5-12AWG)
Knock Out
Locking Nut
Circuit Breaker
Knock Out
J-Box
Connection
Canopy
Plastic Crust