WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2014
FEED OPTIONS
Make sure power is o before wiring.
Note the polarity indicator of the track and accessories.
Live End Connector (WEDL / WEDR)
1. Slide live end connector into track and secured screw (Fig 4a).
2. Remove the cover.
3. Bring feed through either the knock-out on the bottom of
the connector or on the side of the connector (Fig 4b).
4. If bringing feed through the knock-out on the bottom of
the connector be sure that the knock-out cover is
installed on the side of the connector.
5. Wiring(Fig 4c).
6. Replace the cover.
FIG 4A: LIVE END CONNECTOR TRACK ENGAGEMENT
FIG 4B: LIVE END CONNECTOR FEED OPTIONS
FIG 4C: LIVE END CONNECTOR WIRING DIAGRAM
INSTALLATION INSTRUCTION
W Track Surface Mount 120V
WT4, WT8, WT12