Installation & Assembly
08/04/03 Rev1
To Install/ Shorten Pendant:
All Pendant shades use the quick connect adapter to attach to the rail. On the QP-601 the mating piece (top conical
section) for quick connect adapter comes uninstalled. Feed the cable end through the glass shade and the metal
finial. If cable needs to be shortened, make the cut now. To install the top conical section, follow the step-by-step
instructions bellow. NOTE: Pendant cables are co-axial, if the lower screw in step 4 is made too tight, the
inner an outer wire will short. A short circuit will render the entire system in-operative and possibly damage
the transformer. Check all pendant splices for continuity before installing.
Make a clean cut. Slide brass
collar over wire.
Trim 1/8” of insulation from the
inner wire. Position the collar so
that a small section (1/16”) of
braided wire protrudes from the top
of the collar.
Feed inner wire until it reaches the
top set screw position. Feed
braided outer wire and collar into
bottom portion.
Tighten top setscrew first then
lower. Smooth out any bulges in
braided wire. Perform continuity
check before mounting.
1
2
3
4
CAUTION:
Snug but not tight
Check Splice:
Before mounting, with lamp removed
from the socket, check for continuity.
There should be none.
Insert lamp in socket and re-check.
There should now be continuity,
indicating a completed circuit.
Install with power off.
Continuity tester