WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2014 2
INSTALLATION INSTRUCTION
HR90 LED Undercabinet Button Lights
HR-LED90
B) Surface Mounting
NOTE: The cover piece is not needed for surface mounting and may be
discarded.
1. Wires may be run behind the xture or along the mounting
surface. Determine the most convenient location for wire
passage.
2. Screw the back plate to the surface with screws provided.
Ensure that the screw’s heads level with back plate.
3. To wire behind the xture, drill a hole in the surface
sucient to allow the socket wires through.
4. Feed the xture wires through the hole, and connect
the wires to a 24V transformer.
5. Snap the light xture onto back plate. Light xture is held
in place by magnet.
WIRING
Installation within a cabinet require 24V Class 2 transformers.
Class 2 transformers are by denition “Power limited”
(5 amps maximum) and “Inherently Protected” (fused).
Primary wires to the transformer enclosure must follow normal NEC
Chapter 3 wiring techniques. Non-enclosed secondary wiring and
splices are not restricted in concealed spaces.
Output
24V
Input
120V
Back Plate
Light Fixture
Transformer
Output 24V
Input 120V
Back Plate
TRANSFORMERS:
Use to power the HR-90 button light. Below is a list of compatible transformer models and descriptions (sold separately)
Model Number Description
EN-2460-P-AR 60W plug-in transformer, 120V AC
EN-2460-RB2 60W remote transformer, 120V AC
EN-24100-RB2 96W remote transformer, 120V AC
Leveling the screw
Wires behind the xture
Wires along the mounting surface
Light Fixture
Cover Piece
Transformer