INSTALLATION INSTRUCTION
H Track Systems Monopoint
HMP
CAUTION:
Always turn o power at main switch prior to installation to
prevent electrical shock.
• Do not install in damp or wet locations.
• Do not attempt to energize anything other than a track
lighting xture.
OVERVIEW:
The HMP Monopoint attaches to a junction box and accepts
any “H” series line volt and low voltage track head.
1. Attach the cross bar to a junction box using the screws
supplied with the J-box. The screws go through the slotted
holes to allow for adjustment.
2. Connect wires from the monopoint to the ceiling wires
using wire nuts ( not supplied ). White wire joins to white,
black to black. The bare copper ground wire joins to either
a bare or green wire from the ceiling, or may be attached
to a metal
junction box.
3. Secure the monopoint cover to the cross bar using the
colored screws (supplied).
INSTALLING TRACK FIXTURE:
NOTE: on one side of the monopoint the opening is
identied with a line, this indicates the side with two
contacts, to correspond to the contacts on the track head.
On the track xture, pull down on the adapter case while
pushing the contacts into the opening and turning 90 degrees.