Installation Sheet
INSTALLATION INSTRUCTION
Cube Architectural-LED Narrow Beam Wall Mount
DC-WS05-U, DC-WS06-U, DC-WD05-U, DC-WD06-U
WAC Lighting Headquarters/Eastern Distribution Center Western Distribution Center
www.waclighting.com 44 Harbor Park Drive • Port Washington, NY 11050 1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585 Phone (516) 515.5000 • Fax (516) 515.5050 Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
3 / 3
COMPLETING THE INSTALLATION
To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone
sealant) to outline the outside of fixture plate where it meets the wall leaving a space at bottom to allow moisture a
means to escape.
DRIVER REPLACEMENT
1. Loosen the screw and gasket (See FIG.6), remove the cover assembly (See FIG.7).
2. Loosen the LED driver screws, carefully disconnect LED driver connector from LED connector and replace driver
by removing driver mounting screws. (See FIG.8).
LED Driver
FIG. 8
Loosen the
screws and
gasket
FIG. 6
Remove panel
assembly
FIG.7