Technical data

48
W&T
Serial Fiber Optic Interfaces
Termination
Both ends of a Profibus segment must be terminated with a
terminating network which is usually integrated into the
Profibus connectors and can be optionally switched. This
resistor network has two functions: to ensure reflection-free
termination of the line, and to provide a defined rest state on
the lines during the high-impedence phases of the bus system.
To supply the termination network, Pin 6 provides 5 V
referenced to the ground Pin 5, with a maximum load capacity
of 50 mA.
Technical data
Operating mode: RS485 2 wire mode with
automatic control, without echo
Switchover delay: approx. 1µs from send to receive for
RS485 automatic control (can be
factory changed on request)
Baud rate: 0..1,5 Mbps
Transmitted signals: RxD, TxD
Serial connector: 9-pin SUB-D socket
Dimensions: 105x75x22mm
Packing list: 1x Profibus Fiber Optic Interface
1x power adapter for
application in office