Technical data

23
W&T
Centronics > Serial Interfaces
Subject to error and alteration
Connecting the Interface
The Interface has a Centronics input and an RS232 output.
Centronics interface
The Centronics input of the Interface corresponds in its wiring
and signal characteristics to the input of a parallel printer. This
means that any normal printer cable permitting connection of
the data source with a Centronics printer can be used to
connect the Interface input to the data sender.
RS232 interface
Since peripherals also as a rule have RS232 ports configured as
DTE, the connection between the Interface and the peripheral
can usually be made using a serial printer cable configured as
follows:
Supply voltage
The Interface is powered using the supplied AC adapter. The
adapter provides a regulated voltage of 5 V ±5%. Commercially
available, unregulated AC adapters are not suitable for powering
the Interface.
2
3
5
6
7
20
Printer
Interface
data
data
handshake
signal GND
handshake
3
2
20
7
5