W&T Centronics Line Driver Set Manual Centronics Line Driver Set W&T Subject to error and alteration Type Release 20001 1.
W&T Centronics Line Driver Set © 08/2004 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes, you mustn’t use any of our statements without verification. Please, inform us of any error or misunderstanding you come about, so we can identify and eliminate it as soon as possible. Carry out your work on or with W&T products only to the extent that they are described here and after you have completely read and understood the manual or guide.
W&T Centronics Line Driver Set Centronics Line Driver Set The Centronics Line Driver Set #20001 permits unidirectional communication with a peripheral having a parallel interface over a distance of up to 1000 meters. The line driver also provides galvanic isolation up to 500 volts between the connected devices.
W&T Centronics Line Driver Set Both interfaces are connected via a four-conductor, twisted-pair shielded cable. This cable is configured as shown in the following diagram. Serial Line Driver Cable RS422 DB25 male (Printer Side) RS422 DB25 female (Computer Side) 10 22 17 18 14 shell Data Data + Handshake Handshake + GND (opt.