Technical data
86
W&T
describes by how much the state must change in order for a
message to be triggered.
Application Mode
Select OPC Device.
After all the parameters have been entered confirm by clicking
on the Temporary Storage button.
Now in the navigation tree select: Config >> Ports >> Port X >>
Output Mode
Activate here the output mask Binary 1 for the respective
output and confirm by clicking on the Temporary Storage
button.
Now the new settings still need to be activated. Use the Logout
button or select Config >> Session Control >> LogOut.
After clicking on the Save button all the settings are updated in
the Web-IO and the start page is reopened in the default user
mode. The Web-IO can now be accessed by the OPC server.
3.11.5 Program options
After clicking on General options you can specify some details
about the behavior of the OPC server.