Technical data
62
W&T
Now in the navigation tree select: Config >> Device >> Basic
Settings >> Binary1 >> TCP-Server
Local Port
Unless your network administrator has informed you otherwise,
the factory default set Port 49153 may be used.
One reason for changing the factory default set local port may
be for example a fireweall which permits access only to a
particular port.
1
In any case the set local port on the Slave must be
identical to the Server Port entry for the Master.
Client HTTP Port
Specifies which HTTP port to be used for opening the control
connection to the Master box.
Unless otherwise specified, always use Port 80 here.
Binary Trigger
Here you activate the inputs which are to set the corresponding
outputs on the Master.
i
The Web-IO Analog-In/Out allows simultaneous access to
the input from various modes.
This means for example that the inputs which control the
outputs on the Master Web-IO can at the same time be read out
over HTTP.
Application Mode
Select Box2Box Slave
After all the parameters have been entered, confirm by clicking
on the Temporary Storage button.
Now in navigation tree: Config >> Ports >> Port 1 >> Output
Mode