Technical data
51
W&T
Subject to errors and modifications
Remote Port
Enter here the port number you want the UDP application to use
for receiving data when communicating with the Web-IO.
Remote IP Addr
Enter here the IP address of the communication partner.
Binary Trigger
Enter here the inputs whose change of state should be used as
the trigger for sending a UDP datagram (important for event-
triggered applications).
Interval
If you want the status of the inputs to be sent cyclically to the
communication partner, enter here the interval in 100ms
increments.
Example: A value of 300 corresponds to 30 seconds.
1
Please note that for connections using fee-based dial-
up connections too small an interval may result in the
connection not being closed, in turn resulting in permanent
fees!
Application Mode
In the configuration as UDP peer there is no difference between
Socket Device and Compatible 50xxx modes.
After all your settings have been made, send them to the Web-
IO by clicking on the Temporary Storage button.
In addition you must enable the used outputs for Binary mode.
Now in the navigation tree select Config >> Ports >> Port X >>
Output Mode and highlight the desired Binary access.
m Necessary access rights: Administrator
After you have made all your settings, send them by clicking
on the Logout button. Clicking on the Save button activates
settings.