User Manual
Installation and Handling Guidelines for Screw-In Vents
Part Series: PMF100318, PMF100319, PMF100320, PMF100321, PMF100391, PMF100520, PMF100444
GORE
®
Protective Vents are designed to protect in the
harshest environments while quickly and effectively
equalizing the pressure in sealed enclosures. To
maximize the performance of the vent for the lifetime
of your product, please follow the handling and
installation recommendations provided.
Handling Guidelines
•AvoiddirectcontactwithGORE
™
Membrane.
•Donotremoveventcap.
•Donotover-tighten.
•Itisrecommendedtousethefollowingtorquewrenchsizes
forinstallation:
Plasticmoldedparts 16mmsocketorwrench
Metalvent 18mmwrench
Recommendedforce 0.6–0.8Nm(0.44–0.59lbf-ft)
Protective Ring
Enclosure
Through-Hole
A
A
Cross Section A-A
Y
X
PolyVent/M12x1
PolyVent/M12x1.5
PolyVent/M12x1.5 HA
Metal Vent/M12x1.5
ø14.3 ± 0.2
60°
ø10.5
M12 x 1.5
Wall
Corehole
Center line
ø14.3 ± 0.2
60°
ø11
M12 x 1
Wall
Corehole
Center line
Screw-In Vents
Protective Vents
adhesive vents
Topreventunintentionaldamage,anadditionalmeansofprotection
isrecommendedattheinstallationsite.Anexampleofonepossible
meansofprotection,aprotectivering,isshownbelow:
Installation Recommendations
1. Preparation
Makesuremountingsurfaceiscleanandfreeofoils,particles
andothercontaminants.Isopropylalcoholcanbeusedtoclean
themountingsurfaceifneeded.Ensurethesurfaceisdryprior
toinstallation.
2. Positioning
Forbestperformance,ventsshouldbemountedonaflat,vertical
surfacewhereliquidsorothercontaminantswillnotpool.(See
diagram below for mounting recommendation).Goremoldedparts
aredesignedformountingtotheexteriorhousingwall.
Recommended Protective Ring Dimensions by Part
PolyVent
Part PolyVent M12x1.5/ Metal Vent/
Description M12x1 M12x1.5 HA M12x1.5
PMF100320
PMF100321
PMF100318 PMF100391
PartNumber PMF100319 PMF100520 PMF100444
Xdimension 22mm 22mm 24mm
(0.866") (0.866") (0.945")
Ydimension 9mm 8mm 15mm
(0.354") (0.315") (0.590")
Enclosure
Interior
Environment
Housing Wall
®
GORE
®
Protective Vent
GORE
Protective Vent
3. Installation
Toinsertintothehousing,makesurethatthethreadshaveproper
engagementandscrewintothehousing.Ifusingasockettotighten
venttosurface,ensuresocketisfullyengagedwiththeventhousing
beforetightening.
4. Final Inspection
Lookovertheparttoensurethattheventisproperlyseated.
The Gore proprietary membrane is constructed of ePTFE and allows for the free
passage of gases and vapors while at the same time preventing liquid and
particulates from entering the housing.
Recommended Housing Geometry
All dimensions are in mm.