Datasheet

PTV-031-R15-DSH-EN-JUN18
Temperature Testing
Vent durability for a range of
temperatures
METHODS:
IEC 60068-2-1 (to -40 °C)
IEC 60068-2-2 (to +125 °C,
or +150 °C for PolyVent XS)
IEC 60068-2-14
(cycling: -40 °C to +125 °C,
or to +150 °C for PolyVent XS)
Solar Industry Testing
PolyVent XL only
Durability in solar applications
METHODS:
IEC 62108 10.8 (humidity freeze–
high temperature | humidity
followed by freezing temperature)
IEC 62108 10.9 (hail impact)
Flammability and
UV Resistance Testing
Not applicable to Stainless Steel Materials
Resistance to open flame, radiant
heat and ultraviolet light
METHODS:
UL 94 V-0 and UL 746C f1
All non-metal PolyVent
caps/bodies materials
UL 94 V-0
All PolyVent O-ring materials
UL 94 VTM-0
GORE Membranes in PolyVent XS,
Stainless Steel and Ex+
Explosive Environments
Testing
PolyVent Ex+ only
Durability in explosive environment
acc. to IECEx and ATEX
METHODS:
ATEX directive 2014/34/EU
IEC/EN 60079-0
IEC/EN 60079-7
IEC/EN 60079-31
CLASSIFICATION:
Ex II 2G Ex eb IIC Gb
Ex II 2D Ex tb IIIC Db
Mechanical Impact Testing
PolyVent Stainless Steel only
Vent resistance against external
mechanical impact when using
a 60° chamfer and 5.0 ± 0.5 Nm
torque.
METHOD:
IEC 62262 (IK code: IK10)
Ingress Protection Testing
Vent protection against ingress
of particulates and water
METHODS:
IEC 60529
IP65
IP66
IP67
IP68 (extended immersion:
2 meters for 1 hour; or up to
72 hours for PolyVent XS)
ISO 20653
IP69K (available for all vents
except for PolyVent XS)
Humidity Testing
Vent durability in hot, humid
environments (accelerated aging test)
METHOD:
IEC 60068-2-78
TEST CONDITIONS:
85 °C
85% relative humidity
1000 hours
Salt Fog Testing
Vent resistance to salty environments
METHODS:
IEC 60068-2-11 (salt fog)
IEC 60068-2-52 (cyclic salt fog)
Corrosive Gas Testing
Vent durability in corrosive gas
environment (e.g., NO
x
, SO
x
, H
2
S, Cl
x
)
METHOD:
GR-3108-CORE
Vibration Testing
Vent resistance against vibration
METHODS:
ETSI EN 300 019-2-2
IEC 60068-2-64
W. L. Gore & Associates GmbH
Hermann-Oberth-Str. 26, 85640 Putzbrunn, Germany
T +49 89 4612 2211 F +49 89 4612 2302 E protectivevents@wlgore.com
gore.com/protectivevents
FOR INDUSTRIAL USE ONLY. Not for use in food, drug, cosmetic or medical device manufacturing, processing, or packaging operations.
GORE
®
Protective Vent(s) are manufactured under the generic industrial ISO 9001 quality system. No other certifications can be provided by Gore for this
GORE
®
Protective Vent. All technical information given is based on Gore’s previous experiences and/or test results. Gore gives this information to the
best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the
performance of the product can only be judged when all necessary operating data are available. The above information is subject to change and is not to
be used for specification purposes. Gore’s terms and conditions of sale apply to the sale of the products by Gore.
GORE, Together, improving life and designs are trademarks of W. L. Gore & Associates. © 2019 W. L. Gore & Associates GmbH
Environmental Performance
GORE
®
Protective Vents Screw-In Series have been tested by independent laboratories and have been verified to
meet these performance standards. All certificates are available upon request.