Datasheet
Positioning Options for GORE
®
Adhesive Vents Outside the Enclosure
Position on
Enclosure
Advantages Disadvantages
(if no additional mechanical protection is used)
Top
• Rain can block the vent, covering the enclosure’s venting holes.
• To meet IP6x standard, the housing’s venting holes must be less
than 1 mm in diameter. Water, dust and dirt can block these holes.
Vertical wall
• If a mounting bracket or additional vent cover is used,
the housing can meet IP6x standard with holes larger
than 1 mm in diameter. Gore recommends 2.5 to 3 mm
to prevent the capillary effect of water.
• Rain can block venting holes due to capillary effect (sucking water
into the housing through the holes).
• To meet IP6x standard, the housing’s venting holes must be less
than 1 mm in diameter. Water, dust and dirt can block these holes.
Bottom
• Rain cannot block the vent.
• If a mounting bracket or additional vent cover is used,
the housing can meet IP6x standard with holes larger
than 1 mm in diameter. Gore recommends 2.5 to 3 mm
to prevent the capillary effect of water.
Backside
• If a mounting bracket or additional vent cover is used,
the housing can meet IP6x standard with holes larger
than 1 mm in diameter. Gore recommends 2.5 to 3 mm
to prevent the capillary effect of water.
• Rain can block venting holes due to capillary effect (sucking water
into the housing through the holes).
• To meet IP6x standard, the housing’s venting holes must be less
than 1 mm in diameter. Water, dust and dirt can block these holes.
Position on
Enclosure
Advantages Disadvantages
(if no additional mechanical protection is used)
Top
• Rain can cover the membrane and block the vent.
• Mechanical impact can damage the vent (e.g., scratching during
transportation, installation, birds).
Vertical wall
• Rain cannot block the vent.
• If a mounting bracket or additional vent cover is used,
the housing can meet IP6x standard with holes larger
than 1 mm in diameter. Gore recommends 2.5 to 3 mm
to prevent the capillary effect of water.
• Mechanical impact can damage the vent (e.g., scratching during
transportation, installation, birds).
Bottom
• Rain cannot block the vent. • Mechanical impact can damage the vent (e.g., scratching during
transportation or installation).
Backside
• Rain cannot block the vent.
• If a mounting bracket or additional vent cover is used,
the housing can meet IP6x standard with holes larger
than 1 mm in diameter. Gore recommends 2.5 to 3 mm
to prevent the capillary effect of water.
• The enclosure provides mechanical protection for the vent.
Positioning Options for GORE
®
Adhesive Vents Inside an Enclosure
PTV-104-TEC-US-NOV14
International Contacts
FOR INDUSTRIAL USE ONLY. Not for use in food, drug, cosmetic or
medical device manufacturing, processing, or packaging operations.
All technical information and recommendations given here are based on Gore’s previous experiences and/or test
results. Gore gives this information to the best of its knowledge, but assumes no legal responsibility. Customers
should check the suitability and usability in the specific application, since the performance of the product can
only be judged when all necessary operating data are available. The above information is subject to change and
is not to be used for specification purposes.
Gore’s terms and conditions of sale apply to the sale of the products by Gore.
GORE and designs are trademarks of W. L. Gore & Associates.
© 2014 W. L. Gore & Associates, Inc.
Australia +61 2 9473 6800
Benelux +49 89 4612 2211
Brazil +55 11 5502 7800
China +86 21 5172 8299
France +33 1 5695 6565
Germany +49 89 4612 2211
India +91 22 6768 7000
Italy +39 045 6209 240
Japan +81 3 6746 2572
Korea +82 2 393 3411
Mexico +52 81 8288 1281
Scandinavia +46 31 706 7800
Singapore +65 6733 2882
South Africa +27 11 894 2248
South America +55 11 5502 7800
Spain +34 93 480 6900
Taiwan +886 2 2173 7799
United Kingdom +44 1506 460123
USA +1 410 392 4440
W. L. Gore & Associates, Inc.
401 Airport Road • Elkton, MD 21921 • USA
Phone: +1 410 506 7812 (USA) • Toll-free: +1 800 523 4673 (USA)
Fax: +1 410 506 8749 • Email: protectivevents@wlgore.com
gore.com/protectivevents
Optimal Vent Positioning