Datasheet

Corrosive Gas Testing
Vent durability in corrosive gas
environment (e.g., NO
x
, SO
x
,
H
2
S, Cl
x
)
Method:
GR-3108-CORE
Vibration Testing
(not applicable to
PolyVent Supra)
Vent resistance against
vibration
Method:
ETSI EN 300 019-2-2
IEC 60068-2-64
Flammability Testing
Resistance to open flame
and radiant heat
Method:
UL 94 V-0
PolyVent InSet carrier ring
UL 94-HB
PolyVent Standard and
High Airflow caps and bodies
UV Resistance Testing
(not applicable to
PolyVent Supra)
Vent resistance to
ultraviolet light
Method:
ASTM G155-05a
(1,000 hours)
Product Name
PolyVent Supra PolyVent InSet
PolyVent Standard PolyVent High Airflow
Product Number
VE0006GSV
PMF200271
PMF200128 PMF200484 PMF200521
Product Performance Characteristics
Typical airflow 35 ml / min (dp = 70 mbar) 200 ml / min (dp = 70 mbar)
450 ml / min (dp = 70 mbar) 2500 ml / min (dp = 70 mbar) 2000 ml / min (dp = 70 mbar)
Laminate: membrane / backing material ePTFE / Polyester (PET) ePTFE / – ePTFE / Polyester (PET) ePTFE / Polyester (PET) ePTFE / Polyester (PET)
Membrane characteristic Oleophobic Oleophobic Oleophobic Hydrophobic Oleophobic
Vent body & cap: material
Silicone Outer hull: Silicone
/
Carrier ring: PA
Polybutylene Terephthalate (PBT) Polybutylene Terephthalate (PBT) Polybutylene Terephthalate (PBT)
Vent body & cap: color Black Outer hull: clear / Carrier ring: black Black (similar to RAL 9004) Black (similar to RAL 9004) Black (similar to RAL 9004)
O-ring material EPDM 50 Shore A EPDM 50 Shore A EPDM 50 Shore A
Installed height (to the inside)
1.5 mm 1.4 mm
2.9 mm 2.9 mm 2.9 mm
Installed height (to the outside)
1.5 mm
0.0 mm (when inside-mounted) 5.7 mm 5.7 mm 5.7 mm
Traceability No No Yes: Individually laser-marked Yes: Individually laser-marked
Yes: Individually laser-marked
Design and Dimensions
Units are in mm
Recommended Installation
Units are in mm
• Install on a flat, vertical housing surface where
water or other contaminants will not pool.
• Install vent with cap on exterior of housing.
• New PolyVent InSet is designed to be mounted from
inside the enclosure. (It can also be mounted from
outside, but inside-mounting is recommended.)
Salt Fog Testing
Vent resistance to salty
environments
Methods:
IEC 60068-2-11
(salt fog)
IEC 60068-2-52
(cyclic salt fog)
O / 6.4
70 °
0.1
4 0.15
0,5 0.1
Housing wall
GORE
TM
Membrane O-Ring 5.2x2.6
12.9
O / 17
O / 7.8
4.5 0.05
0.1
p p p p p